这是我的第一篇文章,所以请原谅我:-)
背景:我有一个RAID5安装程序,它有4个磁盘,这些磁盘多年来一直工作得很完美。在一个驱动器失败后,我安装了新的驱动器,在那里进行重建,但是它会将新驱动器标记为智能状态失败。
硬件: HP Proliant ML350 G6,6Gb内存,Xeon E5620,BIOS D22 Windows服务器2008R2 (更新)智能阵列P410i 4x 300 6Gb磁盘10k
情境:我买了6个新硬盘,在重建数组的过程中,它的智能状态失败了。我已经尝试了6个驱动器中的5个,并且都得到了相同的错误。
我所做的:更新到最新的FW的raid控制器和几个硬盘驱动器。
我尝试用raid1设置另一个逻辑驱动器,使用其中的两个新驱动器来测试它们,并且没有出现任何问题。
所有驱动器都已插入并在开机期间取出。
思考和问题:五个人真的都被打破了吗?
有什么办法可以清除智能故障状态吗?
下面是来自ACU的一份新的报告:https://dl.dropboxusercontent.com/u/15772069/report-4bef4a9c-00000cf8-00000000.zip,其中重要的一点是:
ACU Version 8.70.9.0
Diagnostic Module Version 5.2.64.0
INFOMGR Version 6.0.1.0
Time Generated Monday November 23, 2015 9:22:40AM
Device Summary:
Smart Array P410i in Embedded Slot
Consolidated Error Report:
Controller: Smart Array P410i in Embedded Slot
Device: Physical Drive 1I:1:2
Message: The physical drive has failed.
Controller: Smart Array P410i in Embedded Slot
Device: Physical Drive 2I:1:6
Message: Physical Drive State: Predictive failure. This physical drive is predicted to fail soon.
Controller: Smart Array P410i in Embedded Slot
Device: Physical Drive 2I:1:7
Message: Physical Drive State: Predictive failure. This physical drive is predicted to fail soon.
Report for Smart Array P410i in Embedded Slot
---------------------------------------------
Smart Array P410i in Embedded Slot : Device Error Report
Device Severity Error
--------------------- -------- ----------------------------------------------------------------------------------------
Physical Drive 1I:1:2 Critical The physical drive has failed.
Physical Drive 2I:1:6 Warning Physical Drive State: Predictive failure. This physical drive is predicted to fail soon.
Physical Drive 2I:1:7 Warning Physical Drive State: Predictive failure. This physical drive is predicted to fail soon.
我把硬盘换成了另一批,现在看来智能staus没问题,但有时Windows会抱怨故障块之类的。S
这6个智能状态失败的新驱动器现在在另一个服务器中。它是一个ML350 G6,在P410i控制器和驱动器上都有最新的固件(我认为)。我已经把所有的6个驱动器放入一个新的RAID5驱动器,并刚刚初始化它完成。它似乎工作得很好,但仍然是聪明的状态失败。
我做了一个CTRL全部显示配置细节,这是输出。有什么办法可以重新设置智能主销吗?
Smart Storage Administrator CLI 2.60.18.0
检测Controllers...Done。为受支持的命令列表键入“帮助”。输入"exit“关闭控制台。
` => ctrl全部显示配置细节
插槽0(嵌入式)总线接口: PCI插槽:0序列号:5001438005EDDF 40缓存序列号: PACCQ9SY70JU控制器状态: OK硬件修改:C固件版本: 6.64-0重建优先级:介质扩展优先级: 15秒表面扫描模式:支持空闲并行表面扫描:不支持队列深度:自动监视器和性能延迟: 60分钟电梯排序:启用不一致性修复策略:禁用等待缓存:禁用表面分析不一致性通知:禁用后提示超时:0秒缓存板出现:真实缓存状态:永久禁用缓存状态详细信息:缓存是禁用的,因为一个或多个附加电池不支持当前运行的固件。缓存比: 25%读/ 75%写写缓存:禁用总缓存大小: 256 MB可用总缓存内存: 144 MB无电池写入缓存:禁用缓存备份电源:电池/电容器计数:1电池/电容器状态:支持失败(替换电池) SATA :端口的真实数量:2个内部驱动程序名称: HpSAMD.sys驱动程序版本: 8.0.4.0 PCI地址(Domain:Bus:Device.Function):0000:04:00.0主机串行编号: CZJ941003H消毒擦除支持:假主启动卷:无辅助启动卷:无
端口名称: 1I端口ID: 0端口连接号:0 SAS地址:5001438005EDDF 40端口位置:内部
端口名称: 2I端口ID: 1端口连接号:1 SAS地址:5001438005EDDF 44端口位置:内部
内部驱动笼在端口1I,框1,好的
Power Supply Status: Not Redundant
Drive Bays: 4
Port: 1I
Box: 1
Location: Internal
物理驱动器1I:1:1 (端口1i:方框1:bay 1,SAS HDD,300 GB,预测失败)物理驱动器1I:1:2 (端口1i:方框1:bay 2,SAS HDD,300 GB,预测失败)物理驱动器1I:1:3 (端口1I:框1:bay 3,HDD,300 GB,预测失败)
内驱笼在端口2I,方框1,好的
Power Supply Status: Not Redundant
Drive Bays: 4
Port: 2I
Box: 1
Location: Internal
物理驱动器2I:1:5 (端口2i:方框1:bay 5,SAS HDD,300 GB,预测失败)物理驱动器2I:1:6 (端口2i:框1:bay 6,SAS HDD,300 GB,预测失败)物理驱动器2I:1:7 (端口2i:框1:bay 7,HDD,300 GB,预测失败)
数组:接口类型: SAS未使用空间:0 MB (0.0%)使用空间:1.6TB (100.0%)状态: OK数组类型:数据
Logical Drive: 1
Size: 1.4 TB
Fault Tolerance: 5
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 64 KB
Full Stripe Size: 320 KB
Status: OK
Caching: Disabled
Parity Initialization Status: Initialization Completed
Unique Identifier: 600508B1001030354544444634300500
Disk Name: \\.\PhysicalDrive0 (Disk 0) (Bus: 0,Target: 4,Lun: 0)
Mount Points: Offline 500 MB Partition Number 1, C:\ 146.0 GB Partition Number 2, D:\ 1.2 TB Partition Number 3
Logical Drive Label: A0017FDF5001438005EDDF40CEA0
Drive Type: Data
LD Acceleration Method: All disabled
physicaldrive 1I:1:1
Port: 1I
Box: 1
Bay: 1
Status: Predictive Failure
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Drive exposed to OS: False
Logical/Physical Block Size: 512/512
Rotational Speed: 10000
Firmware Revision: HPDG
Serial Number: 6SE52A2P0000B213CFP2
WWID: 5000C500437249DD
Model: HP EG0300FAWHV
Current Temperature (C): 33
Maximum Temperature (C): 62
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Sanitize Erase Supported: False
Shingled Magnetic Recording Support: None
physicaldrive 1I:1:2
Port: 1I
Box: 1
Bay: 2
Status: Predictive Failure
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Drive exposed to OS: False
Logical/Physical Block Size: 512/512
Rotational Speed: 10000
Firmware Revision: HPDG
Serial Number: 6SE51A8S0000B213BAGM
WWID: 5000C5004371B7C5
Model: HP EG0300FAWHV
Current Temperature (C): 33
Maximum Temperature (C): 68
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Sanitize Erase Supported: False
Shingled Magnetic Recording Support: None
physicaldrive 1I:1:3
Port: 1I
Box: 1
Bay: 3
Status: Predictive Failure
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Drive exposed to OS: False
Logical/Physical Block Size: 512/512
Rotational Speed: 10000
Firmware Revision: HPDG
Serial Number: 6SE519840000B212DHLM
WWID: 5000C500437278E1
Model: HP EG0300FAWHV
Current Temperature (C): 31
Maximum Temperature (C): 63
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Sanitize Erase Supported: False
Shingled Magnetic Recording Support: None
physicaldrive 2I:1:5
Port: 2I
Box: 1
Bay: 5
Status: Predictive Failure
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Drive exposed to OS: False
Logical/Physical Block Size: 512/512
Rotational Speed: 10000
Firmware Revision: HPDG
Serial Number: 6SE521XZ0000B213B62Z
WWID: 5000C50043760E91
Model: HP EG0300FAWHV
Current Temperature (C): 32
Maximum Temperature (C): 63
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Sanitize Erase Supported: False
Shingled Magnetic Recording Support: None
physicaldrive 2I:1:6
Port: 2I
Box: 1
Bay: 6
Status: Predictive Failure
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Drive exposed to OS: False
Logical/Physical Block Size: 512/512
Rotational Speed: 10000
Firmware Revision: HPDG
Serial Number: 6SE519140000B213A6SG
WWID: 5000C5004371FB05
Model: HP EG0300FAWHV
Current Temperature (C): 33
Maximum Temperature (C): 67
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Sanitize Erase Supported: False
Shingled Magnetic Recording Support: None
physicaldrive 2I:1:7
Port: 2I
Box: 1
Bay: 7
Status: Predictive Failure
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Drive exposed to OS: False
Logical/Physical Block Size: 512/512
Rotational Speed: 10000
Firmware Revision: HPDG
Serial Number: 6SE5194L0000B213BC7W
WWID: 5000C50043720255
Model: HP EG0300FAWHV
Current Temperature (C): 31
Maximum Temperature (C): 60
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Sanitize Erase Supported: False
Shingled Magnetic Recording Support: None
设备编号:250个固件版本: RevC WWID: 5001438005EDDF4F供应商ID: PMCSIERA型号: SRC 8x6G
=>`
在init完成之后,这里也有一个新的ADUreport:https://dl.dropboxusercontent.com/u/15772069/ADUReport%20after%20init.zip
发布于 2015-11-23 09:33:51
假设所有5个新的HDs都是正确的类型,它们都不太可能是错误的。我们也遇到了一个类似的问题:新磁盘的HP ProLiant NAS经常出现故障,我们通过更换磁盘控制器来解决这个问题。
https://serverfault.com/questions/738287
复制相似问题