我想在两台服务器(10.0.0.32和10.0.0.192)的cluster.There上运行web应用程序。当我尝试在10.0.0.192上运行这个应用程序时,我得到了下面的错误。
顺便说一下,我在10.0.0.32上使用adminserver。我可以从10.0.0.32 adminserver控制服务器10.0.0.192,没有任何问题。
####<Dec 30, 2013 3:02:36 PM EET> <Error> <HTTP> <dell-PC> <10-0-0-192> <[ACTIVE] ExecuteThread: '0' for queue: 'weblogic.kernel.Default (self-tuning)'> <<WLS Kernel>> <> <> <1388408556025> <BEA-101083> <Connection failure.
java.io.IOException: A complete message could not be read on socket: 'weblogic.servlet.internal.MuxableSocketHTTP@4bd7f3dd:Socket[addr=/10.0.0.32,port=55179,localport=7002] - idle timeout: '30000' ms, socket timeout: '5000' ms', in the configured timeout period of '60' secs
at weblogic.socket.SocketMuxer$TimerListenerImpl.timerExpired(SocketMuxer.java:1076)
at weblogic.timers.internal.TimerImpl.run(TimerImpl.java:293)
at weblogic.work.SelfTuningWorkManagerImpl$WorkAdapterImpl.run(SelfTuningWorkManagerImpl.java:545)
at weblogic.work.ExecuteThread.execute(ExecuteThread.java:256)
at weblogic.work.ExecuteThread.run(ExecuteThread.java:221)
发布于 2014-01-02 13:43:28
原因:
上述错误表示默认配置的超时期限'60‘秒不足以将完整的消息传输到服务器。
解决方案:
将weblogic控制台中的完整消息超时时间增加到480秒:
服务器-->协议-->常规->高级属性->完整消息超时
您必须重新启动服务器。
无法在套接字:'weblogic.rjvm.t3.T3JVMConnection'“on WebLogic : weblogic.rjvm.PeerGoneException:上读取完整消息;嵌套异常为: java.io.IOException:在配置的超时期限'60‘秒内,无法在套接字:'weblogic.rjvm.t3.T3JVMConnection@12c22dd4’上读取完整消息
为此,我们可以通过设置参数来增加超时时间
-Dweblogic.CompleteT3MessageTimeout=
-Dweblogic.CompleteMessageTimeout=
https://stackoverflow.com/questions/20840295
复制